Quick answer: add up the watts of everything you run at the same time, multiply by 1.25 for a safety buffer, then divide by 800 to get KVA. A typical 3 bedroom home needs 15 to 20 KVA, a small office 15 to 20 KVA, a medium hospital 100 to 200 KVA, and a large cold room 100 KVA and above.

How It Works

1

Tick your appliances

Add everything you run at the same time, with quantities.

2

See your load

We add a 25% safety buffer for you.

3

Get your size and price

See the right Genbrite-Ghaddar and YORC sizes, side by side.

4

Send it on WhatsApp

One tap sends your result to us for a pro forma.

Generator Size Calculator

Step 1 · Your appliances
Not listed? Add it

Generator Size Guide for Nigerian Homes and Businesses

Use these tables to find a starting size for your building. All sizes include the 25% safety buffer. "Soundproof from" is the lowest Links Energies price for a super silent or soundproof generator in that size range, VAT inclusive.

Homes

Home typeTypical loadRecommended sizeSoundproof from
1 bedroom flat1,500 to 3,000W9 KVA₦8,039,355 Genbrite 9 KVA
2 bedroom flat3,000 to 5,000W9 to 15 KVA₦8,039,355 Genbrite 9 KVA
3 bedroom house5,000 to 10,000W15 to 20 KVA₦9,080,695 Genbrite 15 KVA
4 bedroom duplex8,000 to 15,000W20 to 30 KVA₦10,476,721 Genbrite 20 KVA
Large mansion15,000 to 30,000W30 to 60 KVA₦12,247,650 Genbrite 30 KVA

Businesses

Business typeTypical loadRecommended sizeSoundproof from
Small shop or kiosk500 to 2,000W9 KVA₦8,039,355 Genbrite 9 KVA
Small office (5 to 10 staff)3,000 to 8,000W15 to 20 KVA₦9,080,695 Genbrite 15 KVA
Medium office (10 to 30 staff)8,000 to 20,000W20 to 40 KVA₦10,476,721 Genbrite 20 KVA
Supermarket or large shop10,000 to 25,000W20 to 45 KVA₦10,476,721 Genbrite 20 KVA
Restaurant or fast food5,000 to 15,000W15 to 30 KVA₦9,080,695 Genbrite 15 KVA
Filling station5,000 to 12,000W15 to 20 KVA₦9,080,695 Genbrite 15 KVA
Hotel (20 rooms)20,000 to 50,000W40 to 80 KVA₦14,191,741 Genbrite 40 KVA
Hotel (50+ rooms)50,000 to 100,000W80 to 150 KVA₦20,212,021 Genbrite 80 KVA
School or college10,000 to 40,000W20 to 60 KVA₦10,476,721 Genbrite 20 KVA

Hospitals and clinics

FacilityTypical loadRecommended sizeSoundproof from
Small clinic or pharmacy3,000 to 8,000W15 to 20 KVA₦9,080,695 Genbrite 15 KVA
Diagnostic centre8,000 to 25,000W20 to 45 KVA₦10,476,721 Genbrite 20 KVA
Small hospital (20 to 50 beds)25,000 to 60,000W45 to 100 KVA₦14,034,264 Genbrite 45 KVA
Medium hospital (50 to 150 beds)60,000 to 150,000W100 to 200 KVA₦21,460,505 Genbrite 100 KVA
Large hospital (150+ beds)150,000W and above200 to 500 KVA₦39,454,716 Genbrite 200 KVA

Churches

Church sizeSeatingRecommended sizeSoundproof from
Small fellowship or branchUnder 100 seats9 to 20 KVA₦8,039,355 Genbrite 9 KVA
Medium church100 to 500 seats30 to 60 KVA₦12,247,650 Genbrite 30 KVA
Large church or auditorium500 to 2,000 seats80 to 200 KVA₦20,212,021 Genbrite 80 KVA
Mega church or arena2,000+ seats200 to 500 KVA₦39,454,716 Genbrite 200 KVA

Cold rooms

Cold roomWhat it runsRecommended sizeSoundproof from
Small walk in cold roomCompressor plus lights20 to 30 KVA₦10,476,721 Genbrite 20 KVA
Medium cold roomSeveral compressors45 to 60 KVA₦14,034,264 Genbrite 45 KVA
Large cold room or poultry processingMultiple rooms and machines100 KVA and above₦21,460,505 Genbrite 100 KVA

Prices: Links Energies Ltd (RC: 9474133), October 2026. Your exact price is confirmed on your pro forma invoice.

Real Client · Cold Room

"I lost ₦10 million before finding Links Energies."

MIDEKASH Chicken Ltd runs a cold room in Lagos. Power failures had cost the business over ₦10 million in spoiled stock. Links Energies delivered a 100 KVA generator in April 2026, and the cold room has had steady power since.

Cold rooms are where wrong sizing hurts most. Compressors pull a big current when they start, so a generator that looks big enough on paper can still trip. That is why we ask for your compressor ratings before we recommend a size.

How to Calculate Generator Size: The Formula

This is the method engineers use, made simple.

  1. List what runs at the same time. Only count appliances you actually use together on a normal day.
  2. Find each appliance's watts. It is printed on the label. A 1.5hp AC uses about 1,200 watts, a fridge about 300, a ceiling fan about 75.
  3. Add them up. Example: 2 ACs (2,400W) + 1 fridge (300W) + 4 ceiling fans (300W) + 10 LED bulbs (150W) + 2 TVs (300W) = 3,450 watts.
  4. Add 25%. Running a generator at full capacity shortens its life. 3,450W × 1.25 = 4,312 watts.
  5. Convert to KVA. Divide by 1,000, then by 0.8. 4,312 ÷ 1,000 ÷ 0.8 = 5.4 KVA. The nearest size above is the Genbrite-Ghaddar 9 KVA.

Motors need extra. ACs, pumps, compressors and welding machines draw two to three times their running watts for a moment when they start. If you run several at once, go one size up or ask us to check.

Read the Spec Sheet Before You Pay

The spec sheet is the only proof of what is inside the canopy. Check these five things on any quote, from us or anyone else.

Prime vs standby rating

Prime is what the generator gives you all day. Standby is a short emergency rating. A "100 KVA" sold on its standby figure gives you less power for daily use.

Engine model

Look for the exact model, for example John Deere 4045HFG20, not just "John Deere". Different brands often use the same engine, so compare the engine, not only the badge.

Alternator

The alternator makes the electricity. Check the brand and model, for example Leroy Somer TAL044D.

Fuel use at 75% load

This is your real running cost. Most sites run between 50% and 75% load.

Warranty terms

Years or hours, whichever comes first, and what voids it. Get it in writing before you pay.

Diesel Use by Generator Size

Fuel use for Genbrite-Ghaddar generators, in litres of diesel per hour.

ModelSizeAt 75% loadAt full load
KT99 KVA2.45 L/hr
KT1515 KVA4.4 L/hr
KT2020 KVA5.8 L/hr
DT4040 KVA7.67 L/hr10 L/hr
KT4545 KVA11.6 L/hr
DT6060 KVA10.4 L/hr13.8 L/hr
DT8080 KVA13.9 L/hr18.4 L/hr
DT100100 KVA16.7 L/hr22.2 L/hr
DT120120 KVA21.2 L/hr27.7 L/hr
DT150150 KVA25.4 L/hr34.0 L/hr
DT200200 KVA35 L/hr44.7 L/hr
DT250250 KVA40 L/hr53 L/hr
DT300300 KVA56.0 L/hr70.6 L/hr

Source: Genbrite-Ghaddar Machinery leaflets. Compiled by Links Energies Ltd (RC: 9474133). For YORC fuel figures, ask us on WhatsApp.

Generator Size Questions

How do I calculate what generator size I need in Nigeria?

Add up the wattage of all the appliances you want to run at the same time. Multiply the total by 1.25 for a safety buffer. Divide by 1,000 to get kilowatts, then divide by 0.8 to convert to KVA. Choose the nearest generator size above that number. The calculator on this page does it for you.

What size generator do I need for a 3 bedroom house in Nigeria?

A typical 3 bedroom house with 2 air conditioners, a fridge, a TV, fans and lights needs between 5,000 and 10,000 watts, which works out to a 15 KVA to 20 KVA generator. A Genbrite-Ghaddar 15 KVA super silent generator is ₦9,080,695, and a YORC 20 KVA soundproof generator is also available, with its current price sent on WhatsApp. Add a borehole pump or more ACs and you may need 30 KVA.

What size generator does a small office need?

A small office with 5 to 10 computers, 1 or 2 ACs, lights and a printer usually needs 5,000 to 12,000 watts, so a 15 KVA to 20 KVA generator.

What size generator does a cold room need?

It depends on the compressors. A small walk in cold room usually needs 20 KVA to 30 KVA, and a large cold room or poultry processing site needs 100 KVA and above. Compressors draw a high current when they start, so send us the compressor ratings on WhatsApp and we size it for you. MIDEKASH Chicken Ltd runs its cold room on a 100 KVA generator from Links Energies.

What size generator does a hospital need?

A small clinic needs 15 KVA to 20 KVA. A small hospital usually needs 45 KVA to 100 KVA, and a medium hospital 100 KVA to 200 KVA. Theatres, ICU equipment and X-ray machines need careful sizing, so send us your equipment list.

Is KVA the same as KW?

No. KW is the power your appliances actually use. KVA is the rating of the generator. To convert KW to KVA, divide by 0.8. A 16 KW load needs a 20 KVA generator.

What happens if my generator is too small?

It runs at or above full capacity all the time. That causes overheating, higher fuel use, a shorter engine life, and sudden shutdowns.

How much fuel does a generator use?

It depends on the size and the load. For example, a Genbrite-Ghaddar 100 KVA DT100 uses about 16.7 litres of diesel per hour at 75% load and 22.2 litres at full load. The fuel table on this page shows each Genbrite model.

How much does a generator cost in Nigeria?

At Links Energies, soundproof generators start from ₦8,039,355 for a 9 KVA Genbrite-Ghaddar super silent generator, and open set Genbrite generators start from ₦6,811,328. Prices are VAT inclusive.

Get the Right Size, First Time

Send us what you want to power. We reply with the right size, price and delivery date, usually within minutes.